Skip to main content
. Author manuscript; available in PMC: 2017 Jul 20.
Published in final edited form as: J Neurosci Methods. 2016 Mar 2;274:179–190. doi: 10.1016/j.jneumeth.2016.02.025

Table 3.

Annotation experiments.

Spike Number Time cost [min] Efficiency measures
EEG User Manual DTW-TM Manual DTW-TM Time saved [%] Speed-up [%]
S1 Expert1 833 890 53.2 8.3 84.4% 640.6%
Expert2 947 1048 23.0 12.0 47.7% 191.2%
Expert3 940 934 38.0 5.5 85.6% 692.2%
S2 Expert1 390 388 58 11.3 80.6% 515.5%
Expert2 800 737 23.3 17.4 25.4% 134.0%
Expert3 383 391 22.7 4.8 79.0% 475.3%
S3 Expert1 182 179 15.4 6.8 55.8% 226.5%
Expert2 183 177 17.9 13.4 25.3% 133.8%
Expert3 159 173 15.4 3.7 75.8% 413.7%
S4 Expert1 1689 1719 108.4 11.5 89.4% 940.2%
Expert2 1582 1601 26.9 5.5 79.6% 491.2%
Expert3 1802 1777 61.8 5.5 91.1% 1122.3%
S5 Expert1 292 301 18.9 3.4 81.3% 535.3%
Expert2 850 874 23.0 10.8 53.2% 213.5%
Expert3 304 323 17.5 1.2 93.1% 1447.1%
Average 69.8% 554.8%