Table 3.
Treatment | A (μmol m−2s−1) | E (mmol m−2s−1) | gs (mmol m−2s−1) | WUEinst A E−1 | WUEi A gs −1 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DOY | 128 | 173 | 244 | 128 | 173 | 244 | 128 | 173 | 244 | 128 | 173 | 244 | 128 | 173 | 244 |
PS-SG | 13.3 | 10.9b | 3.6b | 5.84 | 5.92 | 5.42 | 231b | 283 | 189 | 2.31 | 1.84 | 0.68b | 57.8 | 38.5b | 19.5b |
FS-SG | 14.2 | 11.9ab | 6.5a | 5.99- | 5.86 | 5.18 | 250ab | 273 | 178 | 2.37 | 2.03 | 1.25a | 56.8- | 43.5ab | 36.5a |
PS-Access | 15.1 | 14.7a | 6.8a | 6.31 | 6.42 | 5.56 | 271a | 278 | 215 | 2.39 | 2.29 | 1.24a | 56 | 52.8a | 31.6a |
Sig. | ns | * | * | ns | ns | ns | * | ns | ns | ns | ns | * | ns | ** | * |
prior whole canopy system setup (May 18, DOY 128) and right after first and final dismantling (22 June, DOY 173 and 1 September, DOY 244, respectively). Instantaneous water use efficiency (WUEinst) and intrinsic (WUEi) were calculated accordingly. PF = partially sprayed. FS = fully sprayed.
* and ** denote significant differences between treatments at P < 0.05 and 0.01 according to within column mean separation performed with SNK test and showed by small letters. ns = not significant.