Skip to main content
. 2017 Feb 24;6(3):e004730. doi: 10.1161/JAHA.116.004730

Table 3.

Procedural Data

PR (n=79) OCT‐Erosion (n=62) P Value
PCI procedure
Stent treatment 77 (97.5) 49 (79.0) <0.001
No of stent/culprit lesion 1.27±0.52 1.26±0.51 0.887
Total stent length, mm 34.2±20.7 30.1±18.0 0.192
Mean stent diameter, mm 3.2±0.43 3.1±0.43 0.275
Baseline TIMI flow grade
TIMI flow grade 0 10 (12.7) 2 (3.2) 0.0013
TIMI flow grade 1 5 (6.3) 2 (3.2)
TIMI flow grade 2 25 (31.6) 8 (12.9)
TIMI flow grade 3 39 (49.4) 50 (80.7)
Final TIMI flow grade ≤2 14 (17.7) 2 (4.8) 0.015
Distal embolization 27 (34.2) 5 (8.1) <0.001

Data are presented as number (percentage) or mean±SD. P values were calculated using t test for continuous variables and Fisher exact test for categorical variables. OCT indicates optical coherence tomography; PCI, percutaneous coronary intervention; PR, plaque rupture; TIMI, thrombolysis in myocardial infarction.