Table 4.
PR (n=61 Stents) | OCT‐Erosion (n=46 Stents) | P Value | |
---|---|---|---|
Edge dissection | 9/61 (14.8) | 4/38 (10.5) | 0.764 |
Proximal | 2/56 (3.6) | 1/38 (2.6) | 0.731 |
Distal | 7/61 (11.5) | 3/38 (7.9) | 0.817 |
In‐stent dissection | 35 (57.4) | 17 (37.0) | 0.036 |
Thrombus | 35 (57.4) | 8 (17.4) | <0.001 |
Thrombus score | 12.1±13.9 | 7.9±11.5 | 0.095 |
Thrombus volume, mm3 | 1.23±1.86 | 0.42±0.41 | 0.027 |
Malapposition | 27 (44.3) | 10 (21.7) | 0.015 |
Malapposed area, mm2 | 0.83±0.39 | 0.53±0.52 | 0.045 |
MLA, mm2 | 6.0±1.7 | 6.1±2.0 | 0.695 |
MLD, mm | 2.6±0.4 | 2.7±0.8 | 0.688 |
Maximum stent area, mm2 | 8.5±2.3 | 8.2±2.5 | 0.470 |
Data are presented as number (percentage) or mean±SD. P values were calculated using t test for continuous variables and Fisher exact test for categorical variables. MLA indicates minimum luminal area; MLD, minimum luminal diameter; OCT, optical coherence tomography; PCI, percutaneous coronary intervention; PR, plaque rupture.