Table 1.

Parameters used in the Monte Carlo calculations for two known and two hypothetical scintillators.

Lu2SiO5:Ce,Ca (LSO) LaBr3:Ce Ultra-fast Perfect
Size (mm) 3 × 3 × 30 3 × 3 × 30 3 × 3 × 30 3 × 3 × 30
Interaction length μ for 511 keV photons (cm) 1.2 2.3 1.2a 1.2a
Refractive index n 1.82 2.1 2a 1.5 and 2.0a
Scintillator Fano factor 6.5 1 1a 1a
Photons per 511 keV Mtot 20 000 38 000 20 000a >10 000a
Rise time τr (ns) 0.021 (Nemallapudi et al 2015) 0.2 (Glodo et al 2005) 0.0a 0.0a
Decay time τd (ns) 28 (Nemallapudi et al 2015) 18 (Glodo et al 2005) 1a 0.0a
a

Hypothetical values.