Skip to main content
. 2017 Jul 10;11(7):7447–7456. doi: 10.1021/acsnano.7b03859

Table 1. Hydrodynamic Size Measurements from DLS for Polystyrene and Hydrogel Nanoparticles and Statistics from Single-Nanoparticle SPRI Measurements for Polystyrene and Hydrogel Nanoparticles and Gas Vesicles.

nanoparticle diameter (nm) standard deviation (nm) ⟨Δ%RNP standard deviation (s) 95% CI skewness (g) μa σb no. of NPs
PS (A) 85 25 0.34 0.10 0.01 0.59 –1.13 0.31 354
PS (B) 170 40 2.19 0.48 0.05 0.68 0.76 0.21 365
                   
HNP 271 55 1.67 0.43 0.05 0.60 0.48 0.27 324
HNP + 2 μM melittin 272 65 2.79 0.52 0.08 0.02 1.01 0.20 172
HNP 272 50 0.90 0.27 0.03 0.55 –0.15 0.31 289
HNP + 500 nM ConA 357 75 3.6 1.3 0.2 0.79 1.22 0.37 307
HNP + 500 nM ConA + 1 mM Man 338 65 2.04 0.60 0.07 0.05 0.66 0.36 270
HNP + 500 nM ConA + 10 mM Man 320 55 1.74 0.41 0.05 0.30 0.53 0.24 241
Mega GV c –0.49 0.26 0.03 –1.28 –0.84 0.52 274
Ana GV –1.07 0.44 0.04 –1.53 –0.0083 0.38 395
Halo GV –3.0 1.5 0.2 –0.74 0.95 0.58 345
a

Log-normal PDF location parameter.

b

Log-normal PDF scale parameter.

c

Size measurements for GVs are reported in Table 2.