Skip to main content
. 2017 Jul 27;7:6654. doi: 10.1038/s41598-017-06311-y

Table 2.

Detailed performance of the CD4+ and CD8+ T lymphocyte cell type classifiers.

Training Test
Output cell type (number of cell) Sensitivity (%) Output cell type (number of cell) Sensitivity (%)
CD4+ T cell CD8+ T cell CD4+ T cell CD8+ T cell
Input cell type CD4+ T cell 54 12 81.82 Input cell type CD4+ T cell 25 4 86.21
CD8+ T cell 6 71 92.21 CD8+ T cell 6 29 82.86
Specificity (%) 92.21 81.82 87.41 (overall) Specificity (%) 82.86 86.21 84.38 (overall)

The identification accuracy and its sub-parameters, sensitivity and specificity, were also presented.