Figure 1.

Figure 1

The microfluidic cell retention device. (a) Cell retention by hollow fiber membranes and microfluidic cell retention device. (b) The schematic of the spiral microfluidic cell retention device. The channel size is 26 mm × 26 mm with 8 loops and its volume is 28 μL. The width is 600 μm, and outer and inner depths are 130 μm and 80 μm, respectively. 10.5 million/mL CHO cells occupied their equilibrium positions near the inner wall and went to the inner outlet. The cell-limited harvest stream flowed into the outer outlet. The two streams from outlets were collected in the tubes. The cell concentration of the harvest stream (outer outlet) had 0.3 million cells/mL with the cell retention efficiency of 97%. Scale bar, 500 μm.