Table 2.

Geometric (region volume) and dosimetric (dose delivered on average to the regions) characterization of the lung regions showing a statistical significant difference between groups (P<.05) according to the 3 applied statistical schemes

S volume, cm3 Statistical mapping scheme
T
TFCE
t
14.7
109
603
RILD Non-RILD RILD Non-RILD RILD Non-RILD
Median dose, Gy 2.35 1.45 5.89 3.74 8.21 5.00
Range, Gy (0.12–8.69) (0.03–7.10) (0.27–13.10) (0.03–12.41) (0.93–12.11) (0.33–14.95)
P value .005 .011 .001

Abbreviations: RILD = radiation-induced lung injury; TFCE = threshold-free cluster enhancement

P values express the significance (Mann-Whitney U test) of the mean dose difference between groups of patients.