Skip to main content
. Author manuscript; available in PMC: 2018 May 1.
Published in final edited form as: IEEE Trans Med Imaging. 2017 Jan 23;36(5):1182–1193. doi: 10.1109/TMI.2017.2656907

Table V.

Reconstruction results based on single MR scan, two orthogonal MR scans, and three orthogonal MR scans

Thickness (mm) 2 3 4 5 6 7
A PSNR(dB) 31.75 26.87 24.40 22.83 21.70 20.67
SSIM 0.985 0.954 0.916 0.876 0.837 0.792
C PSNR(dB) 31.48 26.00 23.14 21.48 20.41 19.47
SSIM 0.987 0.951 0.899 0.845 0.796 0.742
S PSNR(dB) 29.54 24.86 22.57 21.12 20.08 18.89
SSIM 0.978 0.932 0.878 0.824 0.774 0.717
A+C PSNR(dB) 39.18 32.79 29.08 26.72 24.98 23.77
SSIM 0.998 0.989 0.973 0.952 0.924 0.895
A+S PSNR(dB) 38.57 32.16 28.70 26.49 24.79 23.79
SSIM 0.997 0.987 0.970 0.947 0.918 0.892
C+S PSNR(dB) 37.59 31.27 27.63 25.36 23.70 22.53
SSIM 0.997 0.985 0.963 0.933 0.896 0.861
A+C+S PSNR(dB) 42.78 36.68 3237 29.47 27.42 26.10
SSIM 0.999 0.995 0.987 0.974 0.956 0.937

A, C and S stand for Axial, Coronal and Sagittal view scan respectively.