[Table/Fig-9]:
Authors | N | F/video | calcium detection | Statistical analysis | Analysis done on video | Calcium volume computation |
---|---|---|---|---|---|---|
Mintz GS et al., [17] | 1442 | 1043 frames | Semi-automated | CC, ANOVA | None | None |
Sangiorgi G et al., [19] | 13 | 723 frames | Manual | CC | None | None |
Proposed | 19 | ≈ 40,090 frames (≈ 2,110 frames per video) | Automated | CC, Bland-Altman, Student t-test, Wilcoxon test, Mann-Whitney test, and Chi-square test | Yes | Yes |
N: Number of patients, F: Frames, CC: Correlation coefficient.