Skip to main content
. 2017 Jul;5(14):290. doi: 10.21037/atm.2017.07.09

Figure 2.

Figure 2

Schematic representations of three different RMs. In the upper part is represented a SI with a high transpulmonary pressure for a short period of time. In the middle an extended sigh (eSigh) in pressure control mode. A stepwise increased in PEEP with the same driving pressure. These maneuvers have been described for 2 to 4 minutes. In the lower part is represented an eSigh realized in volume control ventilation for 5 to 10 minutes reaching in a high plateau pressure.