Skip to main content
. 2017 Jul 21;13:541–549. doi: 10.1016/j.redox.2017.07.012

Table 1.

Plasma parameters following a glucose challenge and weight of RIP-UCP2 mice.

Glucose Insulin Glucagon Leptin Body mass
(mM) (pg/mL) (pg/mL) (pg/mL) (g)
WT (t0) 5.2 ± 0.8 531 ± 120 41.5 ± 8.4 156 ± 64 27.7 ± 2.0
WT (t15) 21.9 ± 7.2 1037 ± 123 41.7 ± 8.6 166 ± 70
RIP-UCP2 (t0) 5.5 ± 0.8 662 ± 111 55.7 ± 11.1 112 ± 20 29.9 ± 1.5
RIP-UCP2 (15) 24.5 ± 3.7 865 ± 93 51.8 ± 9.8 116 ± 24

The intraperitoneal glucose challenge was performed on 4-month old mice using 2 g of glucose per kg of body weight. Blood samples were collected from tail vein at time 0 (t0) and 15 min after injection (t15). Values are means ± SE, n = 5.