Table 4.

Comparison of HRV parameters between thermoregulatory units

HRV parameter Open crib
(n = 7)
Closed incubator
(n = 13)
p
LF power, ms2
  Before grounding 161 (94) 27.9 (7) 0.003
  Grounding 192 (91) 74.1 (17) 0.12
  After grounding 102 (24) 42.4 (8.1) 0.036
HF power, ms2
  Before grounding 10.2 (4.8) 4.6 (0.9) 0.19
  Grounding 16.0 (8.6) 8.2 (1.4) 0.5
  After grounding 7.8 (3.0) 5.3 (0.8) 0.56
SDNN, ms
  Before grounding 17.3 (3.4) 7.6 (1) 0.001
  Grounding 15.7 (2.8) 11.2 (1.1) 0.12
  After grounding 15.9 (1.9) 9.5 (0.9) 0.008
Heart rate, bpm
  Before grounding 155 (3.7) 160 (3.1) 0.65
  Grounding 154 (4.4) 158 (3.2) 0.82
  After grounding 155 (4.3) 159 (2.8) 0.81

Values are expressed as mean (SE). Comparison of HRV parameters between 7 infants in open cribs compared with 13 infants in closed incubators with heat on. Independent t tests were done on the natural log-transformed data of all the parameters displayed. p < 0.05 is significant.

LF, low-frequency; HF, high-frequency; HRV, heart rate variability; SDNN, standard deviation of beat-to-beat intervals between normal heart beats.