Table 1. Geometric parameters for calculation of gaze and mouse space-time densities.
Geometric parameter | Value |
---|---|
Stimulus size | 900 x 900 pixels |
Pixel size* | 0.265mm |
Voxel size in x/y directions | 10 pixels |
Voxel size in t direction | 10ms |
Perpendicular distance d from eye to screen | 65cm |
Radius of foveal region (β = 2°), calculated as per Eq (1) | 1.135cm = 43 pixels |
Kernel size h for density foveal interaction calculation** | 50 pixels |
Radius of parafoveal region (β = 5°), calculated as per Eq (1) | 2.838cm = 107 pixels |
Kernel size h for density in parafoveal interaction calculation** | 110 pixels |
* Pixel size was calculated as the ratio between screen height (cm) and height of the stimulus image (pixels).
** Radius rounded to the first next multiple of voxel size in x/y directions.