Skip to main content
. 2017 Aug 4;7:7308. doi: 10.1038/s41598-017-06504-5

Figure 5.

Figure 5

Fatigue crack initiation detected by CT. - Fatigue cracks (blue), the pore that initiated the crack (red), and all other pores (green) within a 1 mm thick slice centred around the plane of the crack, detected by CT after (a) 70 k, (b) 100 k and (c) 120 k cycles. In (a) and (b) multiple crack tidemarks show the detected crack size every 1 k cycles following first detection of the crack.