Skip to main content
. Author manuscript; available in PMC: 2018 Jun 1.
Published in final edited form as: Doc Ophthalmol. 2017 Apr 7;134(3):205–219. doi: 10.1007/s10633-017-9586-x

Table 3.

Mean total retinal thickness (Mean ± standard deviation) for each rat strain (LE = Long-Evans, BN = Brown Norway, SD = Sprague-Dawley) with respect to treated and control eyes at baseline.

Eye Total Retinal Thickness (mean ± standard deviation μm)
LE BN SD
Treated 160.9 ± 11.1 152.5 ± 9.8 154.8 ± 11.6
Control 165.3 ± 5.3 152.7 ± 4.1 154.1 ± 11.0

LE rats had the thickest retinas than compared to BN or SD rats (P=0.04543 for LE vs BN, P=0.0280 for LE vs SD, while BN and SD rat retinal thicknesses did not significantly differ (P=0.9599).