Skip to main content
. 2017 Jun 14;292(31):13068–13084. doi: 10.1074/jbc.M117.791392

Table 3.

Rate constants for mtSSB binding to dT30

Rate constants were derived in globally fitting data shown in Fig. 4. Data were fit with the rate constants linked in a 2:1 ratio as described under “Results,” where k+1 = 2 × k+2 and k−2 = 2 × k−1. Alternatively, the rate constants were unlinked, allowing the four rate constants to be independent variables during data fitting. In each case the S.E. values, shown in parentheses, were estimated from confidence contour analysis providing upper and lower limits with a χ2 threshold of 0.98 (minimum/observed χ2).

k+1,30 k−1,30 k2,30 k−2,30
nm1 s1 s1 nm1 s1 s1
Linked 1.47 (1.42–1.53) 2.39 (2.32–2.47) 0.737 (0.71–0.765) 4.78 (4.64–4.94)
Unlinked 1.48 (1.40–1.57) 2.59 (2.33–2.85) 0.75 (0.673–0.871) 4.39 (3.74–5.21)