Skip to main content
. 2017 Apr 27;40(8):1196–1205. doi: 10.1007/s00270-017-1630-4

Table 3.

Outcomes of filter efficiency in 10 procedures

Parameter (n = 10) C max (µg/ml) AUC (h.mg/L) Filter efficiencya Filter efficiency at time T x (%)b
Pre-filter Post-filter Overall T c10 T cend infusion T cend washout Mean
Mean 1.13 4.29 0.57 86.0 95.4 85.9 77.5 86.3
SEM 0.13 0.28 0.0 2.5 2.1 3.6 8.1 3.7
Median 1.15 4.55 0.49 87.2 100 86.3 84.4 86.2
Minimum 0.50 2.20 0.23 71.1 82.7 63.6 30.0 68.2
Maximum 1.80 5.20 1.30 95.5 100 100 100 100
Range 1.30 3.00 1.07 24.4 17.2 36.4 70 31.8

SEM standard error of the mean

a[(AUCpre-filter − AUCpost-filter)/AUCpre-filter] × 100

b[(Pre-filter concentration) − (post-filter concentration)/(pre-filter concentration)] at time T x

ct10 versus t30: p = 0.013; t30 versus t60: p = 0.290; t10 versus t60: p = 0.051. (p for significance is p < 0.017)