Table 1.
Gavage needle specifications based on mouse size.
Weight of mouse (grams) | Gauge (G) | Length of gavage need (inches) | Ball Diameter (mm) | Shape |
---|---|---|---|---|
<14 | 24 | 1 | 1.25 | Straight |
15 – 20 | 22 | 1, 1.5 | 1.25 | Straight |
20 – 25 | 20 | 1, 1.5, 3 | 2.25 | Straight, Curved |
25 – 30 | 18 | 1, 1.5, 2 | 2.25 | Straight, Curved |
30 – 35 | 18 | 2, 3 | 2.25 | Straight, Curved |