Gavage needle specifications based on mouse size.

Weight of mouse (grams) Gauge (G) Length of gavage need (inches) Ball Diameter (mm) Shape
<14 24 1 1.25 Straight
15 – 20 22 1, 1.5 1.25 Straight
20 – 25 20 1, 1.5, 3 2.25 Straight, Curved
25 – 30 18 1, 1.5, 2 2.25 Straight, Curved
30 – 35 18 2, 3 2.25 Straight, Curved