Table 2.
Parameters of the Typing and Keypad Programs for each Participant
Timing Dur (s) |
Target Characters Keypada |
Target Characters Typingb |
Min, Max | Min Corr (range) |
Max Inc | |
---|---|---|---|---|---|---|
S1 | 60 | 0 1 2 4 5 6 7 8 9. − + |
d f j k | 1, 1 or 2, 4 |
90–240 | 3 |
S2 | 60 | 0 1 2 3 4 5 6 7 8 9. − + / * |
r u a s d f g h j k l; |
1, 1 or 2, 4 |
90– 250 | 3 |
S3 | 60 | 0 1 2 3 4 5 6 7 8 9. − + / * |
q w p o a s d f j k l; z x c v b n m. |
1, 1; 1, 4; or 2, 4 |
90– 250 | 3 |
S4 | 60 | 0 1 2 3 4 5 6 7 8 9 − + / * |
d f j k | 1, 1 or 2, 4 |
90– 230 | 3 |
Note. Timing Dur is the duration in s of a single timing. Target characters were arranged in sets, or groups of 3 characters. Min, Max represents the minimum and maximum number of sets per sample. Min corr and max inc is the minimum number of correct characters and maximum number errors to meet mastery criteria. Because the minimum correct characters varied across steps, a range is presented.
Target Characters Keypad could be placed in any position within a set (e.g., .45, 6+7, 42/, 357).
Target characters for the typing program are listed in the order found on the keyboard, but were presented in different combinations within a set (e.g., fkd, kdf, dfk, jkd).