Skip to main content
. 2017 Aug 17;12(8):e0183078. doi: 10.1371/journal.pone.0183078

Table 5. Tracheobronchial stent Implantation of therapeutic flexible airway endoscopy in children of body weight no more than 5 Kg.

Stent implantation Number (%) Data
Infant / Stent 15 / 20 (100)
 Age (month) Mean ± SE 5.8 ± 2.9
Median; range 5.3; 0.3–10.4
 Body weight (Kg) Mean ± SE 3.9 ± 0.7
Median; range 4.0; 2.3–5.0
 Locations Trachea 10 (58.3)
Carinaa 3 (12.5)
Bronchus 7b (29.2)
Procedural time (minute) Mean ± SE 34.4 ± 13.3
Median; range 35.5; 20.0–55.4
Stented period (month)
 Expired stent 5 / 6 (30.0)
Mean ± SE 18.3 ± 9.3
Median; range 21.6; 1.4–36.5
 Retrieved stent 2 / 3 (15.0)
Mean ± SE 48.6 ± 36.7
Median; range 40.2; 16.7–87.4
Remained stent 8 / 11 (55.0)
Mean ± SE 62.2 ± 31.7
Median; range 55.6; 29.2–120.8

aone stent placed from main bronchus cross over carina and end at the low trachea.

b2 in right main bronchus and 5 in left main bronchus.