Published in final edited form as: IEEE Trans Med Imaging. 2016 Dec 21;36(4):983–993. doi: 10.1109/TMI.2016.2643565

TABLE II.

Comparison between Frequency selective AS-PAM and FD-PAM

Experimental Data

Back-propagation method Bandwidth (#bins) Runtime (Sec) FWHM (Axial) SBNR>10 (# images)
Harmonics Ultra-harmonics Broad-band Harmonics Ultra-harmonics Broad-band
FD-PAM #42
#126
0.97±0.01
2.85±0.02
17.3±4.8 (med: 6.2) 14.3±3.0 (med: 13.4) 14.4±4.0 (med: 11.8) 29.6±21.1 (#214/780) 24.8±17.7 (#21/780) 18.8±6.6 (#9/780)
AS-PAM #42
#126
0.18±0.002
0.48±0.001
22.1±6.0 (med: 0.6) 20.6±5.7 (med: 19.6) 23.4±6.2 (med:20.3) 28.2±17.7 (#204/780) 23.1±15.0 (#23/780) 19.2±11.7 (#9/780)

TD-PAM 6.42 MHz 44.5±0.6 All frequencies 18.8±5.9mm(med: 17.4) All frequencies 26±16.8 (#106/780)

FWHM is expressed in mm. The FWHM was estimated by data-fit of the line profiles.