Table 1.

Acquisition protocols of clinical torso PET/MR imaging and PET/MR mammography (used at Yeungnam University Hospital)

TE/TR(ms) FOV(mm) Matrix Resolution Acquisition time (min)
Torso PET/MR
 PET (5 bed × 3 min/bed) 594 4.2 × 4.2
 Dixon VIBE for AC 1.23/3.60 400 172 × 172 1.6 × 1.2 00:32 × 5
 Axial fs T2 HASTE 67/1,000 400 180 × 320 1.7 × 1.3 00:54 × 5
 Coronal T2 HASTE 76/1,000 450 232 × 256 1.8 × 1.8 00:59 × 5
PET/MR mammography
 PET (1 bed for 25 min) 594 4.2 × 4.2
 Dixon VIBE for AC 1.23/306 400 172 × 172 1.6 × 1.2 00:32
 Axial T1 9.6/683 340 250 × 384 1.4 × 0.9 01:32
 Axial fs T2 72/5,200 340 269 × 384 1.3 × 0.9 00:18
 DWI 86/10,300 340 77 × 192 2.5 × 2.0 03:36
 DCE 1.43/4.02 340 276*384 1.2 × 0.9 08:28
 Sagittal fs T2 3.68/8.29 340 256 × 320 0.8 × 0.6 03:16
 Axial VIBE 1.43/4.02 340 296 × 384 1.1 × 0.9 02:50

AC attenuation correction, DCE dynamic contrast-enhanced imaging, DWI diffusion-weighted imaging, fs fat-saturated, HASTE half-Fourier acquisition single-shot turbo spin echo, VIBE volume-interpolated breath-hold examination