Table 1.

a) Diffusion-weighted imaging sequence parameters
Parameter Values
Pulse sequence Diffusion-weighted spin-echo echo-planar-imaging
Slice thickness 10 mm
Interslice gap 2 mm
TE 45 ms
TR 3,000 ms
Image matrix 112 x 112
FOV 40 x 40 cm
Partial fourier acquisition 75 %
Parallel imaging accelerating factor 2
b) Fat quantification imaging sequence parameters
Parameter Values
Pulse sequence Spoiled GRE, MRI-M
Slice thickness 8 mm
Interslice gap 0 mm
TE 1.15, 2.30, 3.45, 4.60, 5.75, 6.90 ms
TR 120 – 270 ms
Flip angle 10°
Image matrix range 160 x 256 to 192 x 256
Base FOV 44 x 44 cm
NEX 1
Parallel imaging accelerating factor None
Bandwidth ± 1,480 Hz/Px

Notes: TE = time to echo; TR = repetition time, FOV = field of view; NEX = number of excitations

Notes: GRE = gradient-recalled echo; MRI-M = magnitude-based magnetic resonance imaging; TE = time to echo; TR = repetition time; FOV = field of view; NEX = number of excitations; Hz = Hertz; Px = pixel