. 2017 May 5;4(Pt 4):400–410. doi: 10.1107/S2052252517005140
Parameter TRL–grease TRL–F-127 TRL–grease BR–LCP–F-127 BR–LCP
Nozzle diameter (µm) 150 100 100 100 100
SLS beamline PXII PXII PXII PXII PXII
Wavelength (Å) 1.033 1.033 1.033 1.033 1.033
Space group P6122 P6122 P6122 P63 P63
Unit-cell parameters, a, b, c (Å) 93.0, 93.0, 130.0 93.0, 93.0, 130.2 93.1, 93.1, 130.0 62.2, 62.2, 110.7 62.2, 62.2, 109.6
α, β, γ (°) 90, 90, 120 90, 90, 120 90, 90, 120 90, 90, 120 90, 90, 120
No. collected images 20456 11188 18156 13285 42457
Hit rate (%) 94 55 58 93 98
No. crystal hits/indexed images 19222/4529 6124/4549 10533/4529 12383/4229 41701/4218
Indexing rate§ (%) 24 74 43 34 10
Resolution range 25.0–2.0 25.0–2.0 25.0–2.0 25.0–2.3 25.0–2.3
Completeness (%) 99.9 (100) 99.9 (100) 99.9 (100) 99.9 (100) 99.9 (100)
Multiplicity 241.2 (154.9) 353.3 (217.8) 277.3 (167.8) 149.3 (106.4) 191.6 (130.7)
I/σ(I) 4.9 (3.3) 5.3 (0.9) 5.3 (2.3) 6.5 (2.8) 6.5 (1.9)
R mrgd-F 23.4 (48.4) 43.3 (242.7) 31.0 (89.1) 24.3 (73.5) 28.9 (120.1)
CC1/2 82.3 (59.8) 92.6 (42.5) 84.8 (50.5) 94.3 (67.6) 94.9 (62.1)
Overall Wilson B factor (Å2) 16.4 34.0 22.2 42.2 47.8

A similar number of randomly chosen images were taken for comparison.

Worse statistics due to the very high stream velocity required for stable flow under the conditions of the experiment.

§

Differences in indexing rates are related to sample preparation. A too-high crystal concentration in the sample resulted in many multiple lattices containing diffraction images in the data set (as manifested by a very high hit rate). These were not always indexed by nXDS, thus giving a low indexing rate.