References | No. Patients | Disease Site/Dye Type | Findings |
---|---|---|---|
How et al72 | 100 | Endometrial patent blue dye+ radiotracer | ≥1 SLN detected in 92% of cases Bilateral mapping rate—72% 11% had LN metastases Sensitivity of SLN algorithm 89% (1 false negative) |
Sinno et al73 | 71 | Endometrial ICG vs. ISB | ICG bilateral mapping rate—78.9% ISB bilateral mapping rate—42.4% 7% had LN metastases All metastases were detected using SLN algorithm ICG may be superior to ISB for SLN ISB may be less effective in obese patients |
Beavis et al74 | 30 | Cervix ICG |
≥1 SLN detected in 100% of cases Bilateral mapping rate—87% 16.7% had LN metastases All metastases were detected using SLN algorithm |
ICG indicates indocyanine green; ISB, isosulfan blue; LN, lymph node; SLN, sentinel lymph node.