Table 2.

Precision of low-cost sensors raw output (raw) and calculated mass concentration based on the regression model (mass) expressed as the mean coefficient of variation (CV, %) by aerosol type.

Aerosol DC1700 Sharp DN Sharp GP

Small Bin Large Bin
number concentration mass raw mass Voltage mass Voltage mass
0.9% Salt Aerosol 2.2 1.4 7.2 - 27 5.9 14 5.9
5% Salt Aerosol 2.2 1.4 15 - 24 5.4 51 4.8
Arizona Road Dust 4.3 3.1 5.0 - 27 1.7 5.0 1.9
Diesel Fume 14 1.8 12 - 17 0.8 15 0.9
Welding Fume 9.0 8.0 14 - 30 7.1 2.0 1.7
Overall Mean 7.4 3.1 11 - 25 4.2 17 3.1