Skip to main content
. Author manuscript; available in PMC: 2017 Sep 1.
Published in final edited form as: Aerosol Sci Technol. 2016 Mar 10;50(5):462–473. doi: 10.1080/02786826.2016.1162901

Table 6.

Evaluation of mass concentrations estimated with the DC1700 with reference to those measured with the SMPS and APS. Based on DC1700 particle concentrations less than 106 particles/cm3

Aerosol Data Pairs Slope ± Std. Error Intercept ± Std. Error (μg/m3) r R2 % Bias
0.9% Salt 21 0.9 ± 0.041,2 14 ± 7.0 0.991 0.98 4.01,2
5% Salt 21 0.8 ± 0.05 21 ± 7.0 0.991 0.98 7.01,2
Arizona Road Dust 18 1.2 ± 0.04 10 ± 26 0.981 0.98 −18
Diesel Fume 21 1.1 ± 0.051,2 −51 ± 23 0.95 0.91 −38
Welding Fume 18 0.9 ± 0.071,2 71 ± 67 0.981 0.95 −3.01,2
1

meets EPA criterion

2

meets NOISH criterion