Skip to main content
. Author manuscript; available in PMC: 2017 Sep 1.
Published in final edited form as: Aerosol Sci Technol. 2016 Mar 16;50(5):497–506. doi: 10.1080/02786826.2016.1164828

FIG 4.

FIG 4

Adjusted collection efficiency of (a) foam and (b) nylon mesh by particle mobility diameter when clean (0 hr) and after loading with metal fume up to 20 hrs (19 mg) foam, and 5 hrs (1 mg) nylon meshes.