Skip to main content
. Author manuscript; available in PMC: 2018 Apr 1.
Published in final edited form as: J Hypertens. 2017 Oct;35(10):2025–2033. doi: 10.1097/HJH.0000000000001424

Table 4. Linear mixed model analysis of the parameters used in the calculation of Pr.

kd s-1 P∞ mmHg ks s-1
Intercept 2.26 (1.86,2.66) 54.3 (50.7,57.9) 17.3 (15.6,18.9)
Slope 0.152 (0.067,0.237) 1.22 (0.78,1.66) -1.61 (-1.96,-1.26)
Fractional Slope 6.7% 2.2% -9.3%
ICC 0.989 0.903 0.944

Intercept – the intercept of the linear mixed model for the 5 aortic sites for all patients, Slope – the beta coefficient of the linear mixed model, % slope – 100 x slope/intercept, ICC – the intraclass correlation coefficient. kd – diastolic rate constant, P - asymptote of the exponential diastolic pressure fall-off, ks – systolic rate constant. The intercept and slope are given as mean (95% confidence interval).