Skip to main content
. Author manuscript; available in PMC: 2018 Oct 1.
Published in final edited form as: J Mech Behav Biomed Mater. 2017 May 31;74:118–127. doi: 10.1016/j.jmbbm.2017.05.039

Figure 5.

Figure 5

Elastic modulus of pulmonary arteries from force curves performed at different working forces. Lung tissue sections cut at 10 μm (A) and 50 μm (B) thicknesses. E values at 97% were used as a reference for statistical comparisons by ANOVA (p < 0.05).