Table 4.

Sensitivity, specificity, and precision of each solvent accessibility (ACC) label, tested on the combined CASP and CAMEO data.

ACC Label Sensitivity Specificity Precision
Our SpX* Acc5** Our SpX Acc5 Our SpX Acc5
B 0.77 0.74 0.75 0.82 0.81 0.80 0.67 0.63 0.62
M 0.45 0.36 0.34 0.80 0.78 0.79 0.54 0.48 0.46
E 0.71 0.67 0.63 0.82 0.79 0.80 0.67 0.62 0.61
*

SPINEX,

**

ACCpro5_ab