Skip to main content
. Author manuscript; available in PMC: 2018 May 1.
Published in final edited form as: IEEE Trans Med Imaging. 2017 Jan 17;36(5):1162–1171. doi: 10.1109/TMI.2017.2654799

TABLE III.

Relative estimation error eP for context-sensitive detector at different sensitivity levels

Sensitivity Mean FPF Error eP PBD SPP-ML SPP-MAP

70% 0.1991 Mean 0.1304 0.1217 0.0923
Median 0.1111 0.0909 0.0714
Quartile 1 0.0281 0 0
Quartile 3 0.2000 0.2000 0.1429

75% 0.2666 Mean 0.1303 0.1362 0.09570
Median 0.1194 0.1111 0.0833
Quartile 1 0.0455 0 0
Quartile 3 0.1818 0.2000 0.1474

80% 0.4110 Mean 0.1256 0.1408 0.1030
Median 0.1111 0.1250 0.0909
Quartile 1 0.0439 0.0625 0.0335
Quartile 3 0.1836 0.2145 0.1428

85% 0.5510 Mean 0.1125 0.1297 0.0927
Median 0.1052 0.1101 0.0833
Quartile 1 0.0420 0.0469 0.0357
Quartile 3 0.1528 0.1818 0.1295