Skip to main content
. 2017 Sep 13;4(3):035003. doi: 10.1117/1.JMI.4.3.035003

Table 6.

For subsurface targets, brain shift correction model performance measured in residual errors (average residual error ± standard deviation of the error) and percent correction (average percent correction ± standard deviation of percent correction).

  Moderate shift (3 to 6 mm) High shift (>6  mm) Moderate and high shift (>3  mm)
Patient # True shift (mm) Residual error (mm) Percent correction (%) True shift (mm) Residual error (mm) Percent correction (%) True shift (mm) Residual error (mm) Percent correction (%)
1 4.6 1.9±1.1 58.6±23.9 7.7 2.6±1.4 66.7±18.2 5.3 2.1±1.2 61.3±22.6
2 4.5 2.6±0.7 42.9±15.6 7.1 1.4* 80.8* 4.7 2.5±0.7 47.0±14.9
3 4.6 2.5±1.5 45.5±32.6 6.9 2.1±1.0 69.0±14.5 5.6 2.3±1.3 57.9±23.2
4 4.1 1.9±1.0 53.5±24.4 N/A N/A N/A 4.1 1.9±1.0 53.5±24.4
5 5.8 3.1* 46.93* 10.6 3.0±1.0 71.3±9.4 9.8 3.1±0.9 68.9±9.2
6 3.8 1.6±0.7 56.4±18.4 N/A N/A N/A 3.8 1.6±0.7 56.4±18.4
7 N/A N/A N/A 10.9 3.5±1.2 68.1±11.0 10.9 3.5±1.2 68.1±11.0
8 4.3 2.1±0.6 50.4±14.0 6.3 2.8±0.5 55.9±7.9 4.7 2.2±0.7 51.9±14.9
9 4.0 3.0 ± 0.7 24.9 ± 17.5 N/A N/A N/A 4.0 3.0 ± 0.7 24.9 ± 17.5

Note: N/A indicates lack of data in a particular subgroup in a patient case.

For details of subsurface shift, as well as number of points in each category, see Table 4.

*

Indicates only one point was present within range.