Table 1. Best results of recovery rate, purity and/or LOD of the current CTC detection technologies.
CTC Detection Technologies a | Without Enrichment | Negative Enrichment | In vivo Enrichment | Without Ligand Capture | With Ligand Capture-Single Modality Enrichment | With Ligand Capture-Dual Modality Enrichment |
---|---|---|---|---|---|---|
Recovery Rate (%) b | - | ∼ 90 | ∼33 | 97 | 95 | >99 |
Purity (%) c | - | 3.64 | - | < 10 | 84 | >92 |
LOD (cells / mL) d | 1 | 1 | 0.12 | 2.2 | 1 | - |
Refs | 23, 27 | 29, 30 | 32 | 35, 37 | 18, 19, 41 | 50 |
The currently reported CTC detection technologies as classified in Scheme 1.
The number percentage of the enriched CTCs to the total CTCs in the blood, which is also named as capture efficiency or enrichment efficiency in some literatures.
The number percentage of the enriched CTCs to the total cells in the enriched samples.
The limit of the CTC concentration in the blood that could be detected.