Skip to main content
. 2017 Jul 11;475(10):2550–2561. doi: 10.1007/s11999-017-5438-y

Table 4.

Results for function

Patient number Clinical followup (months) MSTS (/30) TESS (%) ABD (°) R (°) IR (°) Front elevation (°) Elbow ROM* (°) Patient dissatisfaction
1 31 19 81 30 20 90-T4 80 135/0 No
2 38 11 75 90 20 80-T7 75 140/0 Cosmetic appearance
3 30 20 77 90 20 80-T7 75 140/0 No
4 86 23 82 70 0 80-L4 70 110/−20 Cosmetic appearance
5 32 26 87 30 0 80-T4 30 135/0 Brushing his hair, cosmetic appearance
6 25 27 92 50 10 100-T7 40 140/0 No
7 38 26 85 85 15 90-L4 90 160/0 Fear of a humerus fracture therefore sports restriction

*Flexion/extension (−20 = a deficit of extension); MSTS = Musculoskeletal Tumor Society [13]; TESS score = Toronto Extremity Salvage Score [9]; ABD = abduction; ER = external rotation; IR = internal rotation.