Table 5.
List of measurement error intervals for different tools and devices used
Method | Impact | Experimental error | |
---|---|---|---|
SolidWorks meshing | SolidWorks in‐built mesh generator parameter: meshing resolution tolerance | Geometry | ± 0.011 mm |
3D printing accuracy | Provided by manufacturer | Geometry | ± 0.025 − 0.05 mm |
3D model smoothening | Sandpaper 500, 1000 grit size parameter: estimated max error due to material removal | Geometry | − 0.1 mm |
Silicone filament dimensions | Vernier calipers | Geometry | ± 0.2 mm |
Silicone density | Archimedes suspension method,38 error estimated as 95% confidence interval of 12 measurements | Solid density | ± 0.014 g/cm3 |
Fluid density | Stabinger viscometer | Fluid density | ± 0.0005 g/cm3 |
Fluid dynamic viscosity | Stabinger viscometer | Fluid dynamic viscosity | ± 0.35% |
Fluid kinematic viscosity | Stabinger viscometer | Fluid kinematic viscosity | ± 0.35% |
Tensile testing ‐ displacement | Vernier calipers | Solid mechanical response | ± 0.2 mm |
Tensile testing ‐ load | Incremental water volume injected by 20 ml syringe | Solid mechanical response | ± 0.1 g |
Flow velocity | MRI measurements (see Table 4) | Velocity magnitude | < 0.05· VENC |
Solid position | MRI measurements (see Table 4) | Geometry | Voxel size |