. 2016 Aug 16;16(1):3–15. doi: 10.2463/mrms.rev.2016-0011

Table 1.

Routine magnetic resonance (MR) parameters for 3Tesla (T) imaging of the wrist

Sequence Cor 3D PD FS Cor PD Cor PD FS Ax PD Ax PD FS / Ax T2 FS Sag PD Sag PD FS
Pixel size (mm × mm) 0.35 × 0.35 0.27 × 0.35 0.30 × 0.32 0.4 × 0.4 0.32 × 0.44 0.40 × 0.51 0.23 × 0.32
Slice thickness (mm) 0.35 2 2 2 2 3 3
Slice gap (mm) 0 0.2 0.2 0.2 0.2 0.3 0.3
Number of slices 151 22 22 30 30 22 20–30
FOV (mm) 70 90 90 80 80 70–80 70–80
TE (ms) 29–37 30 27 30 30/70 30 27
TR (ms) 1250–1400 3500 2500–3500 2500 3000/3200 3000 2500–3500
BW (Hz/pixel) 362 194 222 250 153/218 354 175
Echo train length 70–88 13 13 9 11 12 13
NEX 2 1 3 2 2 1 1
Acquisition time (min) ∼5 ∼2.5 ∼4 ∼3 ∼2.5/3 ∼2.8 ∼3.5

Ax, axial; Cor, coronal; Sag, sagittal; 3D, 3-dimensional; PD, proton-density; FS, fat-suppression; FOV, field-of-view; TE, echo time; TR, repetition time; BW, bandwidth; NEX, number of excitations.