Table 3.

Multivariable Predictors of Mortality after LVAD

Adjusted Mortality Hazard Ratio [95% CI] p value

Implant 200910 1.24 [1.12–1.37] <0.001

Age70 1.40 [1.25–1.58] <0.001

Female 1.16 [1.05–1.30] 0.005

DT 1.32 [1.20–1.45] <0.001

BMI, kg/m2 1.01 [1.00–1.01] 0.058

Prior sternotomy 1.37 [1.25–1.50] <0.001

Vasopressor use 1.19 [1.00–1.41] 0.056

Inotrope use 0.95 [0.83–1.09] 0.47

Dialysis 1.85 [1.42–2.41] <0.001

Ventilator support 1.17 [0.97–1.42] 0.11

INTERMACS Profile <0.001
1 1.23 [1.02–1.48] 0.027
2 1.24 [1.07–1.44] 0.004
3 0.95 [0.81–1.11] 0.53
47 (reference) ---- ----

Creatinine, per mg/dL 1.14 [1.09–1.19] <0.001

Albumin, per g/dL 0.92 [0.87–0.98] 0.008

INR 1.05 [0.96–1.16] 0.31