Table 1.

MRI protocol

Sequences Description
Coronal and sagittal T2w fast SE sequences Repetition time/echo time: 2500–5000 ms/100 ms
Matrix: 256 × 256
Echo train length: 16
Acquired signals: 4
FOV: 24 cm
Slice thickness: 4 mm
Intersection gap: 1 mm
Oblique HR images Repetition time/echo time: 2500–5000 ms/100 ms
Matrix: 256 × 256
Echo train length: 16
Acquired signals: 4
Plane: orthogonal to the tumour
FOV: 18 cm
Slice thickness: 3 mm
No intersection gap
Axial T2w fast SE sequences Repetition time/echo time: 2500–5000 ms/100 ms
Matrix: 256 × 256
Echo train length: 16
Acquired signals: 4
FOV: 34–40 cm
Slice thickness: 4 mm
Intersection gap: 0.5 mm
Axial DW images (b-values: 0 and 1000 s mm−2) Single-shot/echoplanar imaging
Echo time/repetition time: minimum/>8000 ms
Signal averages: 8
FOV: 34–40 cm
Matrix: 128 × 128
Slice thickness: 4 mm
Slice spacing: 0.5 mm

DW, diffusion-weighted; FOV, field of view; HR, high-resolution; SE, spin-echo; T2w, T2 weighted.

Axial T2w images were obtained using the same parameters as those for axial DW images; our choice of the FOV was a compromise between voxel size, volume coverage and signal-to-noise ratio, with a maximum FOV of 40 cm. Smaller FOVs (34–40 cm) were also used, depending on the patient characteristics. The total imaging time was 25 min.