Skip to main content
. 2016 Sep;3(3):284–291.

Table 2.

Results of surface and depth microhardness and degree of cure of the studied composites.

Resin composite MT (mm) IT (sec) N MTH (Kg/mm2) SD MBH (Kg/mm2) SD DC(%) SD
Universal (Tetric N Ceram) 2 20 8 44.51 2.54 33.98 1.91 76.52 5.36
40 8 45.72 2.69 35.38 1.43 77.68 6.51
Total 16 45.12 2.60 34.68 1.79 77.10 5.80
4 20 8 44.42 2.40 29.97 3.48 67.91 10.44
40 8 45.31 2.21 33.36 3.35 73.82 8.70
Total 16 44.87 2.28 31.67 3.74 70.87 9.78
6 20 8 44.71 2.44 28.16 2.19 63.07 4.81
40 8 46.63 3.10 32.31 2.89 69.65 8.58
Total 16 45.67 2.87 30.24 3.28 66.36 7.53
bulk fill (Tetric N Ceram Bulk Fill) 2 20 8 44.88 3.10 40.74 3.74 90.95 8.06
40 8 46.03 6.81 42.63 3.09 94.58 17.35
Total 16 45.46 5.15 41.69 3.46 92.77 13.20
4 20 8 44.97 2.98 34.64 2.19 77.42 8.16
40 8 46.25 1.40 36.04 2.33 78.08 6.80
Total 16 45.61 2.35 35.35 2.30 77.76 7.27
6 20 8 45.20 3.10 29.68 2.43 65.93 7.03
40 8 47.38 2.75 33.37 3.07 70.71 8.28
Total 16 46.29 3.05 31.53 3.29 68.33 7.83

MT= Material thickness, IT= Irradiation time, N= Number of samples, MTH= Mean top surface microhardness, SD=Standard deviation , MBH= Mean bottom surface microhardness and DC= Degree of cure