Common problems
|
Potential reasons and solutions
|
[18F]fluoride is not efficiently eluted from the QMA |
· TBA-HCO3 was not prepared correctly. Ensure the concentration is adequate. |
· There are leaks on the TBA-HCO3 vial. Make sure the crimp seal is tight and the septum is not pierced prior to installing it on the IFP. |
· TBA-HCO3 is not in good condition. Order a fresh batch. |
Labeling yield is low |
· There is moisture in the precursor solution. Dry precursor and solvents. |
· Temperature is too low. |
Reaction solution is yellow |
· The product is decomposing due to base. Use less TBA-HCO3. |
· There is too much precursor. Use less precursor. |
· There is too little solvent for the amount of 18F-. Use more solvent. |
Additional peaks on radioHPLC |
· Nitro group is being substituted: reduce the reaction temperature or shorten reaction time. |
Hydrogenation reaction does not work |
· Catalyst is not good. Use a new cartridge. |
· Flow is too fast and does not allow sufficient contact between catalyst and substrate. Decrease flow. |
· Hydrogen pressure is too low. Increase H2 pressure. |
Hydrogen pressure increases dramatically during procedure |
· Cartridge integrity is compromised and solid support is clogging the lines. Stop the flow and shut off the gas. Let radioactivity decay. Remove catalyst cartridge and flush the system. Put a new cartridge. |
Hydrogenation yield is low |
· Too many impurities competing for the catalyst (MeCN, oxalic acid). Decrease amount of impurities or increase mass of precursor (Warning: increasing precursor amount will reduce specific activity). |
Recovery of radioactivity from hydrogenation step is low |
· There is a leak in the system. Check for leaks and backflush into the hydrogen line. |
· Compound is defluorinating in the reactor. Evaluate different reaction conditions (pressure, temperature, flow, etc.). |
Too much radioactivity is lost during filtration |
· Wet the filter prior to use. |
· Use filter with a lower dead volume. |
The final product peak on the HPLC looks broad |
· Too much volume injected. Inject lower amount. Use column with larger diameter. |
· The column is not well conditioned. Condition the column for at least 30 column volumes. |
· pH of the mobile phase is low. Make sure that the pH ≥ 8. |
· Column is not in good condition. Replace column. Use column compatible with basic pH. |