Combination of parameters (r/M,m) that shows best classification performances (AUCmax) of ApEn, SampEn and DistEn with minimum (50 beats) and maximum (1,000 beats) data lengths for two case studies used in this study.

Data length N Complexity measure Elderly vs. Young r/M, m(AUCmax) Healthy vs. Arrhythmia r/M, m(AUCmax)
50 ApEn 1, 2(0.75) 0.9, 5(0.67)
SampEn 1, 2(0.75) 1, 2(0.66)
DistEn 100, 4(0.82) 200, 2(0.94)
1000 ApEn 0.8, 3(0.85) 1, 2(0.92)
SampEn 0.8, 3(0.84) 0.3, 2(0.87)
DistEn 2000, 5(0.82) 400, 5(0.93)