Skip to main content
. 2017 Jul 28;18(5):711–727. doi: 10.1007/s10162-017-0625-9

TABLE 6.

Columns 2–4 show masked thresholds (dB re 1 μA) for on-site probes, for the four subjects of experiment 3 who were tested with the TP_SYM masker. The first column shows the subject and masker electrode tested. Columns 5–7 show the results of unpaired t tests between the two conditions shown at the top of each column. These t tests were performed using the four runs tested with each masker and are not corrected for multiple comparisons. Significant differences at the 5 and 1 % levels are shown by single and double asterisks, respectively

TP_PSA TP_PSA TP_SYM
TP_PSA TP_PSC TP_SYM TP_PSC TP_SYM TP_PSC
AB1,e4 55.2 54.6 55.0
AB2, e4 53.4 52.6 53.5 * **
AB3,e4 55.1 54.6 54.6 *
AB6,e6 53.8 52.9 53.7 ** *
Mean 54.4 53.6 54.2