Skip to main content
. Author manuscript; available in PMC: 2017 Sep 26.
Published in final edited form as: J Electrocardiol. 2016 May 2;49(5):728–732. doi: 10.1016/j.jelectrocard.2016.04.010

Table 2.

Validation of three different algorithms.

AG1 AG2 AG3
Culprit artery
  Sensitivity 0.69 (0.61–0.76) 0.68 (0.60–0.76) 0.62 (0.54–0.70)
  Specificity 0.89 (0.85–0.92) 0.91 (0.87–0.94) 0.95 (0.92–0.97)
  LR+ 6.42 (4.67–8.84) 7.55 (5.33–10.70) 12.21 (7.65–19.49)
  LR− 0.35 (0.27–0.44) 0.35 (0.27–0.44) 0.40 (0.32–0.49)
  A-ROC 0.79 (0.75–0.83) 0.79 (0.75–0.84) 0.78 (0.74–0.83)
Catheterization
  Sensitivity 0.66 (0.58–0.73) 0.65 (0.57–0.72) 0.57 (0.49–0.64)
  Specificity 0.91 (0.87–0.93) 0.93 (0.89–0.95) 0.95 (0.93–0.97)
  LR+ 7.11 (5.00–10.13) 8.74 (5.90–12.95) 12.78 (7.66–21.33)
  LR− 0.38 (0.35–0.47) 0.38 (0.35–0.47) 0.45 (0.38–0.54)
  A-ROC 0.78 (0.74–0.82) 0.79 (0.75–0.83) 0.76 (0.72–0.80)
STEMI activation
  Sensitivity 0.79 (0.72–0.85) 0.79 (0.71–0.85) 0.67 (0.59–0.74)
  Specificity 0.95 (0.91–0.97) 0.97 (0.94–0.98) 0.98 (0.96–0.99)
  LR+ 14.60 (9.36–22.77) 22.92 (13.06–40.21) 33.35 (15.88–70.03)
  LR− 0.22 (0.16–0.30) 0.22 (0.16–0.30) 0.34 (0.27–0.42)
  A-ROC 0.87 (0.84–0.90) 0.88 (0.84–0.91) 0.82 (0.79–0.86)

Values in parenthesis are 95% CI.

LR = likelihood ratio.

A-ROC = area under the receiver operating characteristic curve.