No. Material Sensing mode αme MV m−1 T−1 Limit of detection (λB) (μm m−1 mT−1)
1[31] Terfenol-D/PMNPT d33 2.5 @ 1 kHz 10 pT @ 1 Hz 12
2[15] Metglas/PMNPT d33 52 @ 1Hz 2.8 pT Hz−1/2 22
3[40] Metglas FeBSiC/PZT-5A d33 22 @ 1 Hz N/A 40
4[6] Terfenol-D/PZT-4 d31 4.68 @ 1 kHz N/A N/A
5[8] Terfenol-D/PZT d31 0.6 @ 0.5Hz 1.0 nT Hz−1/2 @ 1 Hz N/A
6(this work) Metglas 2605SA1/PZT-5A d31 6.1 @ 20 Hz 0.6 nT Hz−1/2 @ 100 Hz 79