Skip to main content
. 2017 Sep 6;17(9):2039. doi: 10.3390/s17092039

Table 1.

Comparison of sensor performance parameters with (*) and without deposition of Pd NPs.

Gas Gas or Vapor Pulse Sensor Performance Parameters
Response (%) Response Time (min) Recovery Time (min)
Acetone 1 13.6 7.8 * 6.3 5.9 * 10.1 9.5 *
2 19.4 8.9 * 5.4 12.1 * 24.2 16.6 *
3 12.5 9.2 * 4.4 6.5 * 10.4 15.8 *
2-Propanol 1 - 2.8 * 18.4 6.3 * 5.8 4.5 *
2 3.7 2.6 * 18.2 7.4 * 4.2 4.3 *
3 3.6 2.5 * 18.9 6.5 * 5 4.2 *
Xylene 1 11.6 - 18.5 - 15.5 -
2 11.1 - 17.1 - 19.5 -
Hydrogen 1 1.1 0.8 * 16.2 2.76 * 15.1 10.3 *
2 - 1.2 * - 2.6 * - 10.2 *
3 - 1.06 * - 3.3 * - 12 *