Skip to main content
. Author manuscript; available in PMC: 2018 Sep 1.
Published in final edited form as: J Phys Chem Ref Data. 2017 Aug 8;46(3):033101. doi: 10.1063/1.4991518

TABLE 3.

Data sets considered for the thermal conductivity of liquid germanium at 0.1 MPa

First author Publ. year Puritya (mass %) Technique employedb Uncertainty quoted (%) No. of data Temp. Range (K) Form of datac
Previous reference correlation/values
 Mills13 1996 - - 1 1212 P
Primary data
 Nishi31 2003 - Laser flash (TD) 2.2 19 1218–1399 D
 Yamasue32 2002 99.99 Transient hot wire 5.9 5 1273–1473 P
 Takasuka33 1995 - Laser flash (TD) - 69 1201–1329 D
 Taylor34 1985 - Laser flash (TD) - 12 1218–1296 D
 Crouch35 1982 - Laser flash (TD) - 3 1243–1283 P
Secondary data
 Filippov24 1973 - Temperature wave (TD) 2 1212–1601 D
 Glazov36 1971 HP Guarded heat flow - Concentric cylinders 10 7 1221–1409 D
 Glazov36 1971 HP Guarded heat-flow 10 7 1326–1468 D
a

HP = High Purity grade

b

TD = thermal diffusivity measurement

c

D = diagram, P = tabulated experimental data