Table 1.

Acquisition parameters

TR (ms) TI (ms) Gap (ms) TE (ms) echo spacing (ms) flip angle (°) GRAPPA
T1 3100 1500 na 3.5 na 4 3
PD 2160 na na 3.5 na 4 3
T2* 3700 na na 16 na 4 3
GE-EPI 2400 na 1200 22.8 0.7 90 3
3D GRASE 2000 na 310 29.2 0.7 90; 180 na
TOF 25 na na 3.3 na 22 2
SWI 28 na na 14.4 na 15 2
MB Matrix size slices Voxel resolution averages TA (min)
T1 na 384 × 384 256 0.6 mm 2 14
PD na 384 × 384 256 0.6 mm 1 5
T2* na 384 × 384 256 0.6 mm 1 8
GE-EPI 2 232 × 256 36 0.8 mm na 5 per run
3D GRASE na 28 × 250 16 0.8 mm na 4 per run
TOF na 452 × 576 80 0.4 mm 1 6
SWI na 432 × 576 80 0.4 mm 2 12

Acquisition parameters for all acquired datasets. TR = repetition time; TI = inversion time; gap = silence between acquisitions during which sound is presented, computed as TR – acquisition time of one volume; TE = echo time; GRAPPA = generalized autocalibrating partially parallel acquisition; MB = multiband; TA = acquisition time of the dataset. Voxel resolution was isotropic for all datasets.